White clock icon with a circular arrow and "24h" below, highlighting Tecnogera's full availability on a light gray background.

0800-772-1601

Cold rooms and food

Generator rental for cold storage warehouse

Without power, your cold room heats up and the stock of perishables can be lost in hours.

We rent the generator that keeps refrigeration running in your cold storage warehouse, freezer, or food depot.

  • Keep compressors running when the utility grid fails
  • Receive a free power calculation for your refrigeration
  • Have the generator monitored by telemetry and 24-hour on-call service

Black Friday No Blackout

Condition
Special conditions, defined by the consultant in each proposal
Applies to
Generator rental contracts signed by 11/30/2026
Regulation
On the campaign page

What happens in the cold room when the power goes out?

In the cold chamber, a power outage shuts down the compressors and breaks the cold chain of your stock.

With each hour of blackout, the temperature in the chambers approaches the limit your product can withstand.

Outside the sanitary surveillance storage parameters, the batch becomes a loss and delivery to your distributors is delayed.

That’s why your cold operation generator needs to take over refrigeration alone, day or night.

Black Friday Without Blackout: special conditions for generator rental contracts signed by 11/30.

See the conditions

Power generator for cold chamber, cold storage, and warehouse

In each type of food operation, the cold chamber generator protects a different stage of the cold chain.

Cold storage warehouse

The frozen and chilled chambers rely on the same power. If you store clients’ goods, a blackout affects the stock of several owners at once.

Cold chamber

Even a smaller distributor’s cold chamber needs a generator sized for the compressor start-up. Our models start from the range up to 100 kVA, and engineering indicates which one suits your chamber.

Cold storage

Power keeps the carcass cooling chambers and freezing tunnels along with the production line. A drop in the middle of the shift leaves the product in process out of temperature.

Food warehouse

If your warehouse dispatches perishables at night, the chamber and refrigerated dock need power at that time.

How do we protect Danone’s largest refrigerated distribution center?

Danone Alimentos was seeking supplementary power for the refrigerated distribution center, the largest the company has in the country.

Without refrigeration, the center would fail to meet the sanitary surveillance storage parameters for perishables.

We set up a standby system with a 1,400 kVA generator and a 3,200 amp transfer switch.

To connect the system to the center, we installed over 1,500 meters of cables under ducts.

Maintenance and any equipment replacement are handled by our team, as shown in the Danone Alimentos case study.

How does the generator take over refrigeration with no one on site?

The generator takes over on its own because it is on standby, connected to your warehouse by an automatic transfer switch, the ATS.

In the event of a network failure or a scheduled shutdown, the ATS starts the generator and powers the compressors in seconds.

To have automatic transfer, your operation needs an ATS installed according to the project and commercial proposal.

Our own logistics delivers the generator from the nearest unit, installs it, and performs the load test at your warehouse.

During the contract, telemetry monitors the generator remotely, and our on-call service is available 24 hours, even at night.

How do we calculate the generator for your refrigeration?

We calculate the power based on your compressors, because each motor usually draws several times the normal current at startup.

If the generator is too small, this current can cause a voltage drop and hinder the compressor’s startup.

This calculation is provided at no cost before the proposal and considers the consumption of your chambers and the startup peak.

You can check the models and power ranges on the page of generator rental.

What if your plant’s cooling system stops for maintenance?

During a maintenance shutdown, a rented chiller can enhance the process cooling in your food plant.

Your cold storage during Black Friday and the holidays

If your storage receives holiday stock, power needs to be ensured from Black Friday, on 11/27.

In the Black Friday No Blackout campaign, generator rental contracts signed from 10/16 to 11/30/2026 have special conditions.

Our consultant considers your storage project, timeline, and service region to define these conditions.

They do not combine with other conditions or existing contracts and are subject to credit analysis and availability.

The complete regulations and contact with a consultant are on the Black Friday No Blackout page.

Other campaign segments appear on the energy generator for Black Friday page.

Who already relies on Tecnogera

generator rental client or generator rental servicegenerator rental client or generator rentalgenerator rental client or generator rentalgenerator rental client or generator rentalgenerator rental client or generator rentalgenerator rental client or generator rentalgenerator rental client or generator rental servicegenerator rental client or generator rental

Frequently Asked Questions

How much does it cost to rent a generator for a cold chamber?

The price considers the power in kVA, rental time, fuel consumption, and freight. Our engineering team calculates the power for your compressors at no cost before sending the quote.

What is the generator power for a refrigerated warehouse?

It depends on the number of compressors, chambers, and refrigerated docks you need to keep running. At Danone’s cooled center, for example, we sized a 1,400 kVA generator.

Does the generator start automatically if the cold chamber loses power at night?

In stand-by, it starts automatically at any time, as long as the ATS is included in the project and commercial proposal. The switch from the grid to the generator happens in a matter of seconds.

What fuel does the power generator for a cold storage use?

We have diesel, biodiesel, natural gas, and biogas generator sets for your cold operation.

How long does it take for the generator to arrive at the warehouse?

The time frame depends on the distance to our nearest unit and is provided in writing in your proposal.

Can’t your operation stop?

Get in touch.

Our team of experts is ready to assist you.

The image features the word Tecnogera in lowercase, bold, and orange. The last "a" has a special design: it resembles a bowl or cup, with a white curved detail inside. The white background highlights and enhances Tecnogera's modern look.
24/7 support
0800-772-1601

24/7 support.